181212 and 030101: A/DE77/DE77.HTM
For this page, see
DE77 in English or
DG77 in German.
For the previous page, see
DE76 in English or
DG76 in German.
For the next page, see
DE78 in English or
DG78 in German.
Back to the main page of this colour series, see
../DE in English or
../DG in German.
1. w* setgray is
used in the files "NP" (NA.PS, NP.PS, NA.PDF, NP.PDF)
2. w* setgray and output linearization is used in the files
"FP" (FA.PS, FP.PS, FA.PDF, FP.PDF)
For technical papers with discussion and application of the material, see XY91AE.html
Tables and content of similar data and recommendations about PDF-files, see DE70D.HTM
Table 1. No Output Linearization (OLN) and w* setgray is used to produce the start output (Step S1)
Format PS and Portable Document Format (Version 3.0), File extention NA.PS, NA.TXT, and NA.PDF | Format PS and Portable Document Format (Version 3.0), File extention NP.PS, NP.TXT, and NP.PDF | |||||
Part of test chart | Full part | Upper part | Lower part | Full part | Upper part | Lower part |
Standard data, Landscape orientation | ||||||
Monitor or printer (L=Linear Measurement Data Table; LAB* input) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Monitor (L=Linear Measurement Data Table; XYZ input +2.5%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Printer (L=Linear Measurement Data Table; XYZ input +0.0%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Modified quadratic standard data, Landscape orientation | ||||||
Monitor or printer (L=Linear Measurement Data Table; LAB* input) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Monitor (L=Linear Measurement Data Table; XYZ input +2.5%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Printer (L=Linear Measurement Data Table; XYZ input +0.0%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Table 2. File Output Linearization
(OLF) and w* setgray is used to produce the linearized output
(step S2)
Format PS and Portable Document Format (Version 3.0), File extention FA.PS, FA.TXT, and FA.PDF | Format PS and Portable Document Format (Version 3.0), File extention FP.PS, FP.TXT, and FP.PDF | |||||
Part of test chart | Full part | Upper part | Lower part | Full part | Upper part | Lower part |
Standard data, Landscape orientation | ||||||
Monitor or printer (L=Linear Measurement Data Table; LAB* input) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Monitor (L=Linear Measurement Data Table; XYZ input +2.5%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Printer x (L=Linear Measurement Data Table; XYZ input +0.0%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Modified quadratic standard data, Landscape orientation | ||||||
Monitor or printer (L=Linear Measurement Data Table; LAB* input) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Monitor (L=Linear Measurement Data Table; XYZ input +2.5%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Printer (L=Linear Measurement Data Table; XYZ input +0.0%) |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
200 / 200 / 70 kByte |
Instead of L=Linear LAB* or XYZ data
files other LAB* or XYZ data may be used in the files which change
the output, see the other files:
1. Q=Quadratic data files Q77*, DE77Q.HTM
2. S=Square root data files S77*, DE77S.HTM
3. B=Imange setter data files B77*, DE77B.HTM
4. V=Video corrected data files V77* (not realized)
It is recommended to study first the
three red marked files.
The two files "NP" and "FP"
1. L77E00NP.PDF
(NP: all parts of the test chart
with w* setgray and NO Output Linearisation)
2. L77E00FP.PDF
(FP: all parts of the test chart
with w* setgray and Output Linearisation (OL))
include all parts of the test
charts and show the w* setgray output without and with
Output Linearisation (OL). The two are identical if the LAB* data
or XYZ data at the beginning of the files include linear data.
The three files "FP"
1. L77E00FP.PDF
(00FP: all parts of the test chart)
2. L77E01FP. PDF
(01FP: upper part of the test chart)
3. L77E05FP.PDF
(02FP: lower part of the test chart,
only lower part of Fig. C3)
show all output with Output
Linearisation (OL). The output of the file L77E05FP.PDF (02FP:
lower part of the test chart) looks
darker. Within the file the grey data are changed by a quadratic
function of the original grey data which make the input data between
0 and 1 smaller. Instead of the "linear" input data:
0, 1/15, 2/15, ..., 14/15, 1 the following "quadratic"
input data are used in the file 05FP: 0, (1/15)(1/15),
(2/15)(2/15), ... (14/15)(14/15), 1. Such differences may appear
by a monitor or printer driver. The question is if we can correct
the output failure of such a driver. The answer is Yes.
The 6 steps to verify this are decribed in the following:
General: The
output of the 16 steps of the file L77E05FP.PDF (05FP:
lower part of the test chart) must be compared sample by sample
with the output of the file L77E01FP.
PDF (01FP:
upper part of the test chart).
If possible then choose the transparent ISO/IEC-test chart
no. 3 as reference (available from BAM).
If the transparent test chart is NOT available then choose as
reference the digital output of the file L77E01FP.PDF(01FP:
upper part of the test chart).
The procedure for the comparison of the digital output and the reference output is decribed in DE70R.HTM
-------
For an introduction (archive 2000-2009) to all folders
compared to this folder DE77, see
../DE.HTM in English or
../DG.HTM in German.
For information (archive 2000-2009) about International and
National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.
For information (archive 2000-2009) about colour test charts
and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.
For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.
Back to the main page of the TU web site
(not archive), see
../../index.html in English or
../../indexDE.html in German.
The last link may not work, if you have visited
directly this archive site.
Then go to the main page of one of the
two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.