030401: www.ps.bam.de/BE84/BE84X.HTM
This page in German for "yield and image reproduction properties" with MTL code for Output Linearisation (OL) in FP files , see BG84X
This page in English for "yield
and image reproduction properties" without Output
Linearisation (OL) by NP files , see BE80X
This page in German for "yield
and image reproduction properties" without Output
Linearisation (OL) by NP files , see BG80X
Fig. 1: ISO/IEC-test chart of form 1 with image area frame, see
X84E00NA.EPS / GIF
/ PDF
Fig. 2: ISO/IEC-test chart of form 1 without image area frame,
see Y84E00NA.EPS / GIF
/ PDF
Fig. 3: ISO/IEC-test chart of form 3 without image area frame,
see Z84E00NA.EPS / GIF
/ PDF
Fig. 4: Output layout, fonts and colour definitions of the ISO/IEC-test
chart of form 2, see Y84EL0NA.EPS /
GIF / PDF
Fig. 5: Output layout, fonts and colour definitions of the ISO/IEC-test
chart of form 3, see Z84EL0NA.EPS /
GIF / PDF
1. Other related
test charts for the test of yield, emission and reproduction properties
by different forms
There are similar proposed ISO/IEC-test charts for different
tests and for Colour Workflow (CW) by different input and
output PS operators
without and with MFL and MTL code for Output Linearisation
(OL). Each file produces 10 pages of 2 series times 5 pages and
2 or 3 forms.
The MFL code (Measurement,
Lightness Function and Linearisation) includes the CIELAB lightness
L* data of the start output. The Output Linearisation is produced
by one simple function. The result is a linearisation of the CIELAB
lightness L* of the grey scale.
The MTL code (Measurement, Transfer and Linearisation)
includes three dimensional CIELAB data of the start output. The
Output Linearisation is done by a Transfer (T) of the corresponding
device coordinates (000n*, w*, nnn0*, www*) to CIELAB coordinates
LAB*. The output transfer changes from LAB* to coordinates of
one of the output PS operators no. 0 to 3. The result is a linearisation
of the CIELAB lightness L* of the grey scale
see the paper (2 pages, 92 kByte) BAMLIN.PDF
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSA" letter for the test of yield and
test chart no. 3 according to ISO/IEC 15775 for the test of image
reproduction properties
Input operator no. 0: 000n* setcmykcolor, see CE79
Input operator no. 1: w* setgray, see CE80
Input operator no. 2: nnn0* setcmykcolor, see CE81
Input operator no. 3: www* setrgbcolor, see CE82
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the "LSA" letter for the test of yield and
test chart no. 3 according to ISO/IEC 15775 for the test of image
reproduction properties
Input operator no. 0: 000n* setcmykcolor, see BE79
Input operator no. 1: w* setgray, see BE80
Input operator no. 2: nnn0* setcmykcolor, see BE81
Input operator no. 3: www* setrgbcolorr, see BE82
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSA" letter for the test of yield and
x-form test chart according to DIN 33870 for the L* lightness
measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE83
Input operator no. 1: w* setgray, see CE84
Input operator no. 2: nnn0* setcmykcolor, see CE85
Input operator no. 3: www* setrgbcolor, see CE86
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the "LSA" letter for the test of yield and
x-form test chart according to DIN 33870 for the L* lightness
measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE83
Input operator no. 1: w* setgray, see BE84
Input operator no. 2: nnn0* setcmykcolor, see BE85
Input operator no. 3: www* setrgbcolorr, see BE86
Proposals for digital ISO/IEC-test charts
for the tests of yield, emission and reproduction properties
with the "LSB" lettter including more graphics and
a yield reference chart of 5% visual area coverage
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSB" letter with more graphics for
the test of yield and x-form test chart according to DIN 33870
for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE87
Input operator no. 1: w* setgray, see CE88
Input operator no. 2: nnn0* setcmykcolor, see CE89
Input operator no. 3: www* setrgbcolor, see CE90
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the "LSB" letter with more graphics for
the test of yield and x-form test chart according to DIN 33870
for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE87
Input operator no. 1: w* setgray, see BE88
Input operator no. 2: nnn0* setcmykcolor, see BE89
Input operator no. 3: www* setrgbcolorr, see BE90
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form test
chart according to DIN 33870 for the L* lightness measurement
of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE91
Input operator no. 1: w* setgray, see CE92
Input operator no. 2: nnn0* setcmykcolor, see CE93
Input operator no. 3: www* setrgbcolor, see CE94
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form test
chart according to DIN 33870 for the L* lightness measurement
of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE91
Input operator no. 1: w* setgray, see BE92
Input operator no. 2: nnn0* setcmykcolor, see BE93
Input operator no. 3: www* setrgbcolorr, see BE94
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form
test chart according to DIN 33870 for the L* lightness measurement
and six other test charts for the test of image reproduction
properties
Input operator no. 0: 000n* setcmykcolor, see CE95
Input operator no. 1: w* setgray, see CE96
Input operator no. 2: nnn0* setcmykcolor, see CE97
Input operator no. 3: www* setrgbcolor, see CE98
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form
test chart according to DIN 33870 for the L* lightness measurementx
and six other test charts for the test of image reproduction
properties
Input operator no. 0: 000n* setcmykcolor, see BE95
Input operator no. 1: w* setgray, see BE96
Input operator no. 2: nnn0* setcmykcolor, see BE97
Input operator no. 3: www* setrgbcolorr, see BE98
2. Purpose of
the Yield test without and with Output Linearisation
With the ISO/IEC-test
charts of form 1 to 3 the yield of achromatic printers
is specified. The counted printed pages of the yield test depends
on:
1. The file format (PS, PDF or equivalent)
2. The PDF Reader version of PDF Readers (e. g. , Adobe , GoScript
or Mac OS X)
3. The colour space (CMYN, GREY, OLV) and PS operator (setcmykcolor,
setgray and setrgbcolor) used for the definition of achromatic
colours. There are at least four possibilities without (NP
files) and for with (FP files) Output Linearisation
CMYN (CMYK) and 000n* setcmykcolor
GREY and w* setgray
CMYN (CMYK) and cmy0* setcmykcolor
OLV (RGB) and rgb* setrgbcolor
Remark: The scaling of the output (e. g. of the grey figure
in the test page) for the four possibilities is usually different,
see the test page DE81/10L/L81E00NP.PDF
which uses for different PS operators (setcmykcolor, setgray
and setrgbcolor) on one page.
4. Use of the option "device
raster" or "PDF raster" of the PDF reader which
is present for many printers
5. Use of different resolutions for the output
6. Use of different printing modes, such as "fine print",
"photograde", etc.
7. Interpretation and transformation of the colour space data
(GREY, RGB, etc. ) in the PDF file by the PDF reader or the workflow
The yield may be determined without or with Output Linearisation (OL), for the method see ISO/IEC/WD 19797E:2003. The corresponding NP files and FP files are in Table 1 of BE80X and the following Table 1. Without Output Linearisation the yield value may be very different depending on the above parameters. Many of the above parameters are specific and change according to the version of the computer operating system and e. g. the version of the printer drivers.
It is therefore recommended to use the method of Output Linearisation (OL) for the determination of yield. For this one CIELAB lightness L* measurement is recommended for the 2 times 16 gray steps which are equally spaced in the digital file between 0 and 1. The form 3 is used for the output of the 32 greys. Then the determination of yield is independend of the above seven parameters. But any choise including the transfer from the FP.PS file to a FP.PDF file (e. g. with Adobe Acrobat Distiller) must be constant during the whole yield test procedure.
For Output Linearisation the output of a 16 step grey scale must be measured only once. It is recommended to measure the output of the 16 step grey scale at the end of 1/10 of the declared yield of the manufacturer, e. g. to measure page 250 of the FP file in step S5F01. After printing of 1/10 of the declared yield most of the printers seem to be stable in output until fade. The 16 CIELAB L* lightness data, test date, testing person and the number of 1/10 of the manufacturer yield (e. g. pcount2g=100 instead of 250) must be included arround line 100 of the file Y84EXXFP.PS. Then after the transfer of the PS file to a PDF file the output of the FP.PDF file produces with the same parameters a 5 step grey series in form 1 and a 16 step grey series in form 3 both equally spaced in CIELAB and independend of the above seven parameters.
Remark: Output Linearisation reduce large L* output differences of intended equal L* spacing and real output L* spacing often by a factor 5 to less than 3 in L*, see ISO/IEC/WD 19797E:2003. The additional work to include Output Linearisation was less then 10% of the whole work for the yield test according to practical experience.
3. Version and changes
20030501: Version 2.0 for the test of the yield for monochromatic
electrophotographic printers.
There is a test method without (N=NP file) and with (F=FP file)
Output Linearisation(OL). For the NP and FP files see Table 1
and 2.
4. Test aim and short description of the test procedure with Output Linearisation (F=FP files)
Steps S1F to S3F: Start output and example outputs of form 1, 2 and 3 with output of one page only.
Step S4F produces the ouptut of the series no. 1 and 2 of 5 pages each, in any case one page of form 1 and form 3 and 3 pages of form 2 (ratio 1:3).
Step S5Fi (i=01 to 10) produces the ouptut of the series no. 1 and 10 of 250 pages each, in any case one page of form 1 and form 3 and 248 pages of form 2 (ratio 1:248).
The number 250 is assumed here as 1/10 of the declared OEM yield of the form 2.
5. Test files with Output Linearisation (F=FP files)
Digital ISO/IEC-test chart according to ISO/IEC/FCD 19752:2003 with Output Linearisation (OL) |
Remarks for use and reproduction | Text- (TXT) and PostScript format
(PS); file type P.TXT or P.PS for transfer to Portable Document Format (PDF) |
Step S1F: Start output form 1, one page |
Serves for the start output of the ISO/IEC-test chart, form 1 for the specification and the test of the output size for the yield page with page frame. |
52 / 52 / 20 kByte |
Step S2F: Start output form 2, one page |
Serves for the start output of the ISO/IEC-test chart, form 2 for the specification and the test of the output size for the yield page without page frame (continues form, series and page number) |
52 / 52 / 8 kByte |
Step S3F: Start output form 3, one page |
Serves for the start output of the ISO/IEC-test chart, form 3 for the measurement of the 16 step grey scale with page frame (continues form, series and page number) |
52 / 52 / 8 kByte |
Step S4F: short example
output 2 times (form 1 + form 3 + 3 times form 2), produces 10 pages all together |
Serves for a short example output of the ISO/IEC-test chart, form 1 + form 3 + 3 times form 2 for the specification of the yield (continues form, series and page number) |
52 / 52 / 88 kByte |
Step S5F: Test output:
"yield" 10 times (form 1 + form 3 + 248 times form 2) produces 2.500 pages all together |
Serves for the output of the ISO/IEC-test chart, form 1 + form 3 + 248 times form 2 for the specification of the yield (continues form, series and page number) |
52 / 52 / 33.800 kByte |
The yield is specified as the amount of the printed pages. For a step by step test the files in the format PS, PDF or equivalent of the steps S1F, S2F and S3F may be used. For an automatic test the files in the format PS, PDF or equivalent of the step S5F may be used.
The file of the step S5F produces 2500 pages which are splitted in ten series of 250 pages each. The output may be interrupted, e. g. by the software Adobe Reader at any page. After replacement of a cartridge or input of new pages the output may be continued after this page. A continues form, series and page number is printed on every page.
Date and test person (example "2003-04-01; K. Richter) and test device (example "unknown B(E/G)84") may be replaced arround line 60 in the PS file and appear then on the output of the page frame. The series and page numbers (scount=1 to 10 and pcount=1 to 250) may be also changed. In both cases the PS file must be transferred to a PDF file, e. g. with the software Adobe Acrobat Distiller. Any printer can print this PDF file.
Note: It is recommended to print step by step the pages 1 to 250, 251 to 500, ..., 2000 to 2250, 2251 to 2500 of the steps S4N01, S4N02, ..., S4N09, SN410 with the file Y84GXXFP.PDF (about 33 MByte! which is produced from Y84GXXFP.PS by the software Adobe Acrobat Distiller Version 3.0).
Information about the geometric layout of form 2, the fonts and the colour definitions used in the ISO/IEC-test chart according to ISO/IEC/FCD 19572:2003 in the file formats PS: Y84EL0NP.PS und PDF: Y84EL0NP.PDF
Information about the geometric layout of form 3, the fonts and the colour definitions used in the ISO/IEC-test chart according to ISO/IEC/FCD 19572:2003 in the file formats PS: Z84EL0NP.PS und PDF: Z84EL0NP.PDF
-------
For an introduction (archive 2000-2009) to all folders
compared to this folder BE80, see
../BE.HTM in English or
../BG.HTM in German.
For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.
For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.
For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.
back to the main page of the TU web site
../../index.html in English.
The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.