181101 and 040801: A/BE80/BE80.HTM

For this page, see BE80 in English or BG80 in German.
For the previous page, see BE79 in English or BG79 in German.
For the next page, see BE81 in English or BG81 in German.
Back to the main page of this colour series, see ../BE in English or ../BG in German.

ISO/IEC-test chart for yield test, form 1 to 3
Colour Workflow (CW) by the input operator no. 1
and different output PS operators without and with MTL code for Output Linearisation (OL)
each file produces 10 pages of 2 series times 5 pages and several forms


Fig. 1: Output layout of all the files in the following tables 1 to 3 der form 1, see
X80E00NA.EPS / GIF / PDF


Fig. 2: Output layout of all the files in the following tables 1 to 3 der form 2, see
Y80E00NA.EPS / GIF / PDF


Fig. 3: Output layout of all the files in the following tables 1 to 3 of form 3 (not present in files of the series 79, 80, 81, 82), see
Z80E00NA.EPS / GIF / PDF

This page includes files for the following application:
ISO/IEC-test chart for yield test, form 1 to 3,
Colour Workflow (CW) and Output Linearisation (OL)

Table 1 includes the output files of the Portable Document format (L..NP.PS/TXT/PDF and L..FP.PS/TXT/PDF)
Table 2 includes the output files of the PostScript format (L..NA.PS/TXT and L..FA.PS/TXT).
Table 3 includes the output files of the Portable Document format (L..NP.PS/TXT/PDF and L..SP.PS/TXT/PDF).

To indicate the Colour Workflow (CW) different file names are used at the output. The files have usually the same PS content.

The PS content of the files L..NP.PS, L..NA.PS and L..SP.PS of the Tables 1 to 3 is identical and includes no MTL code.
The PS content of the files L..FP.PS and L..FA.PS of the Tables 1 and 2 is identical and includes the MTL code L..FP.DAT or L..FA.DAT in the file (F).

The output of the files L..FP.PDF and L..SP.PDF must be identical if the MTL code L..SP.DAT is stored within the Distiller Startup Directory during distilling of the PS file L..SP.PS. The files L..FP.PDF and L..SP.PDF have been produced by the software Adobe Acrobat DIstiller Version 3.0. In the first case the MTL code is located in the file L..FP.PS and in the second case the MTL code L..FP.DAT = L..SP.DAT is not in the file L..SP.PS but in the Startup (S) directory of the software Adobe Acrobat DIstiller.

Input PS operator no. 1
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 1
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
L80E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L80E00FP.PS / TXT / PDF L80E00FP.DAT
L80E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L80E01FP.PS / TXT / PDF L80E01FP.DAT
L80E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L80E02FP.PS / TXT / PDF L80E02FP.DAT
L80E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L80E03FP.PS / TXT / PDF L80E03FP.DAT
L80E04NP.PS / TXT / PDF   4 lab* setcolor L80E04FP.PS / TXT / PDF L80E04FP.DAT
L80E05NP.PS / TXT / PDF  5 LAB* setcolor L80E05FP.PS / TXT / PDF L80E05FP.DAT
L80E06NP.PS / TXT / PDF  6 000n* setcmykcolor L80E06FP.PS / TXT / PDF L80E06FP.DAT
L80E07NP.PS / TXT / PDF  7 w* setgray L80E07FP.PS / TXT / PDF L80E07FP.DAT

Table 1: For PDF output with linearising data in File (F); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files* of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
* Files on www server: ..00(NP,FP,NA,FA,SP).

Input PS operator no. 1
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 1
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
L80E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor L80E00FA.PS / TXT L80E00FA.DAT
L80E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray L80E01FA.PS / TXT L80E01FA.DAT
L80E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor L80E02FA.PS / TXT L80E02FA.DAT
L80E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor L80E03FA.PS / TXT L80E03FA.DAT
L80E04NA.PS / TXT   4 lab* setcolor L80E04FA.PS / TXT L80E04FA.DAT
L80E05NA.PS / TXT  5 LAB* setcolor L80E05FA.PS / TXT L80E05FA.DAT
L80E06NA.PS / TXT  6 000n* setcmykcolor L80E06FA.PS / TXT L80E06FA.DAT
L80E07NA.PS / TXT  7 w* setgray L80E07FA.PS / TXT L80E07FA.DAT

Table 2: For PS output with linearising data in File (F); Input PS operator no. 1 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files* of Table 2 it is intended to produce only a PS output and not a PDF output.

The files of the tables 1 to 3 are available for different devices instead of the model device L=Linear. Every device produces with all NP files the same start output. Only for the model device L=Linear of the table 2 the output of the NP and FP in one row is identical. For devices which produce equal output for corresponding colours the output of all FP files in one collum is identical.

In application the output of the NP files for differnet output parameters i*ptrsc is in one collum often different. The output of the FP file of the devices S and Q or of the linearized output devices F, O, and T is different compared to the output of the NP file. The PS MTL code uses the measurement data of up to 256 colours of the start output, see the CIELAB LAB* data at the beginning of the FP files, for the change and the linearisation of the output.

There are NP and FP files for the following devices (they are not available at this side for all devices)
S (Model device =Square Root, leads to a lighter output with the FP file), see BE80S
Q (Model device = Quadrac, leads to la darker output with the FP file), siehe BE80Q
F (PS foto printer, leads to a linearized output with the FP file), see BE80F
O (PS laser printer, leads to a linearized output with the FP file), see BE80O
T (PS laser printer, leads to a linearized output with the FP file), see BE80T
If the files are not available then try for similar modifications the directories DE81, DE84, DE85, DE87, DE95, DE96

Input PS operator no. 1
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 1
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
L80E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L80E00SP.PS / TXT / PDF L80E00SP.DAT
L80E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L80E01SP.PS / TXT / PDF L80E01SP.DAT
L80E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L80E02SP.PS / TXT / PDF L80E02SP.DAT
L80E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L80E03SP.PS / TXT / PDF *) L80E03SP.DAT
L80E04NP.PS / TXT / PDF   4 lab* setcolor L80E04SP.PS / TXT / PDF L80E04SP.DAT
L80E05NP.PS / TXT / PDF  5 LAB* setcolor L80E05SP.PS / TXT / PDF L80E05SP.DAT
L80E06NP.PS / TXT / PDF  6 000n* setcmykcolor L80E06SP.PS / TXT / PDF L80E06SP.DAT
L80E07NP.PS / TXT / PDF  7 w* setgray L80E07SP.PS / TXT / PDF L80E07SP.DAT

Table 3: For PDF output with linearising data in Startup (S); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

*) Please transfer e. g. the PDF file L80E03SP.PS with the file L80E03SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=3. Then this PDF-file produces the same output ans the file L80E03FP.PDF of the Table 2. All L..SP files of the Table 3 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files* of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

The input operator no. 1 and eight output PS operators no. 0 to 7 are used in the files.The input PS operator no. 1 of the NA or NP file are transferred to the output PS operators no. 0 to 7 in the FA, FP or SP file by the PS MTL code.

For further information and discussion of the results in the achromatic case with similar files see DE811

For further information and discussion of the results in the chromatic case with similar files see DE841

Compare the final result in DE811 and DE841. The Colour Workflow (CW) and the Output Linearisation (OL) of the PS MTL code is based on ISO/IEC 15775 and DIS ISO/IEC 19839-X. The PS MTL code is compatible to CIELAB and fulfils the basic user requirements in the field of image technology. The result is the same in the achromatic and chromatic case.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder BE80, see
../BE.HTM in English or ../BG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.