181212 and 030101: A/DE88/DE88S.HTM

For this page, see DE88 in English or DG88 in German.
For the previous page, see DE87 in English or DG87 in German.
For the next page, see DE89 in English or DG89 in German.
Back to the main page of this colour series, see ../DE in English or ../DG in German.

For this page without and with MTL code (N and F file) for OL with CIELAB data of surface colours for different devices:
L=Linear, see DE88L in English and DG88L in German,
S=Square root, see DE88S in English and DG88S in German,
Q=Quadratic, see DE88Q in English and DG88Q in German,
printer F, see DE88F in English and DG88F in German,
printer O, see DE88O in English and DG88O in German,
printer T, see DE88T in English and DG88T in German.

Achromatic ISO/IEC-test chart 3, nnn0* input
Colour Workflow (CW) by the input operator no. 2
and different output PS operators and Output Linearisation (OL)


Fig. 1: Output layout without the MTL code in the N-File (N = No MTL code in the file), see
S88E00N1.PS / TXT / JPG / PDF


Fig. 2: Output layout with MTL code of example CIELAB output data of the device L (L=Linear) in the F-File (F = MTL code in the File), see
S88E00F1.PS / TXT / JPG / PDF

Remark 1: The files of the tables 1 to 3 include the linearising data for the model device L (L=Linear) and the tables 1 to 3 include the linearising data for the model devices S or Q (S=Square Root, Q=Quadratic) or real printer devices F, O or T for the linearized printer output.

Input PS operator no. 2
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 2
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
S88E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor S88E00FP.PS / TXT / PDF S88E00FP.DAT
S88E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray S88E01FP.PS / TXT / PDF S88E01FP.DAT
S88E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor S88E02FP.PS / TXT / PDF S88E02FP.DAT
S88E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor S88E03FP.PS / TXT / PDF S88E03FP.DAT
S88E04NP.PS / TXT / PDF   4 lab* setcolor S88E04FP.PS / TXT / PDF S88E04FP.DAT
S88E05NP.PS / TXT / PDF  5 LAB* setcolor S88E05FP.PS / TXT / PDF S88E05FP.DAT
S88E06NP.PS / TXT / PDF  6 000n* setcmykcolor S88E06FP.PS / TXT / PDF S88E06FP.DAT
S88E07NP.PS / TXT / PDF  7 w* setgray S88E07FP.PS / TXT / PDF S88E07FP.DAT

Table 1: For PDF start output with linearising data (L=Linear) in File (F); Input PS operator no. 2 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files* of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
* Files on www server: ..00(NP,FP,NA,FA,SP).

Input PS operator no. 2
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 2
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
S88E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor S88E00FA.PS / TXT S88E00FA.DAT
S88E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray S88E01FA.PS / TXT S88E01FA.DAT
S88E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor S88E02FA.PS / TXT S88E02FA.DAT
S88E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor S88E03FA.PS / TXT S88E03FA.DAT
S88E04NA.PS / TXT   4 lab* setcolor S88E04FA.PS / TXT S88E04FA.DAT
S88E05NA.PS / TXT  5 LAB* setcolor S88E05FA.PS / TXT S88E05FA.DAT
S88E06NA.PS / TXT  6 000n* setcmykcolor S88E06FA.PS / TXT S88E06FA.DAT
S88E07NA.PS / TXT  7 w* setgray S88E07FA.PS / TXT S88E07FA.DAT

Table 2: For PS start output with linearising data (L=Linear) in File (F); Input PS operator no. 2 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files* of Table 2 it is intended to produce only a PS output and not a PDF output.

Input PS operator no. 2
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 2
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
S88E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor S88E00SP.PS / TXT / PDF S88E00SP.DAT
S88E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray S88E01SP.PS / TXT / PDF S88E01SP.DAT
S88E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor S88E02SP.PS / TXT / PDF S88E02SP.DAT
S88E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor S88E03SP.PS / TXT / PDF *) S88E03SP.DAT
S88E04NP.PS / TXT / PDF   4 lab* setcolor S88E04SP.PS / TXT / PDF S88E04SP.DAT
S88E05NP.PS / TXT / PDF  5 LAB* setcolor S88E05SP.PS / TXT / PDF S88E05SP.DAT
S88E06NP.PS / TXT / PDF  6 000n* setcmykcolor S88E06SP.PS / TXT / PDF S88E06SP.DAT
S88E07NP.PS / TXT / PDF  7 w* setgray S88E07SP.PS / TXT / PDF S88E07SP.DAT

Table 3: For PDF start output with linearising data (L=Linear) in Startup (S); Input PS operator no. 2 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

*) Please transfer e. g. the PDF file S88E03SP.PS with the file S88E03SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=3. Then this PDF-file produces the same output ans the file S88E03FP.PDF of the Table 2. All L..SP files of the Table 3 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files* of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

Input PS operator no. 2
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 2
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
S88E10NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor S88E10FP.PS / TXT / PDF S88E10FP.DAT
S88E11NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray S88E11FP.PS / TXT / PDF S88E11FP.DAT
S88E12NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor S88E12FP.PS / TXT / PDF S88E12FP.DAT
S88E13NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor S88E13FP.PS / TXT / PDF S88E13FP.DAT
S88E14NP.PS / TXT / PDF   4 lab* setcolor S88E14FP.PS / TXT / PDF S88E14FP.DAT
S88E15NP.PS / TXT / PDF  5 LAB* setcolor S88E15FP.PS / TXT / PDF S88E15FP.DAT
S88E16NP.PS / TXT / PDF  6 000n* setcmykcolor S88E16FP.PS / TXT / PDF S88E16FP.DAT
S88E17NP.PS / TXT / PDF  7 w* setgray S88E17FP.PS / TXT / PDF S88E17FP.DAT

Table 4: For PDF linearized output with linearising data of the device (S, Q, F, O or T) in File (F); Input PS operator no. 2 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files* of Table 4 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.

Input PS operator no. 2
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 2
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
S88E10NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor S88E10FA.PS / TXT S88E10FA.DAT
S88E11NA.PS / TXT  1 olv* setrgbcolor and w* setgray S88E11FA.PS / TXT S88E11FA.DAT
S88E12NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor S88E12FA.PS / TXT S88E12FA.DAT
S88E13NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor S88E13FA.PS / TXT S88E13FA.DAT
S88E14NA.PS / TXT   4 lab* setcolor S88E14FA.PS / TXT S88E14FA.DAT
S88E15NA.PS / TXT  5 LAB* setcolor S88E15FA.PS / TXT S88E15FA.DAT
S88E16NA.PS / TXT  6 000n* setcmykcolor S88E16FA.PS / TXT S88E16FA.DAT
S88E17NA.PS / TXT  7 w* setgray S88E17FA.PS / TXT S88E17FA.DAT

Table 5: For PS linearized output with linearising data of the device (S, Q, F, O or T) in File (F); Input PS operator no. 2 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files* of Table 5 it is intended to produce only a PS output and not a PDF output.

Input PS operator no. 2
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 2
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
S88E10NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor S88E10SP.PS / TXT / PDF S88E10SP.DAT
S88E11NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray S88E11SP.PS / TXT / PDF S88E11SP.DAT
S88E12NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor S88E12SP.PS / TXT / PDF S88E12SP.DAT
S88E13NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor S88E13SP.PS / TXT / PDF *) S88E13SP.DAT
S88E14NP.PS / TXT / PDF   4 lab* setcolor S88E14SP.PS / TXT / PDF S88E14SP.DAT
S88E15NP.PS / TXT / PDF  5 LAB* setcolor S88E15SP.PS / TXT / PDF S88E15SP.DAT
S88E16NP.PS / TXT / PDF  6 000n* setcmykcolor S88E16SP.PS / TXT / PDF S88E16SP.DAT
S88E17NP.PS / TXT / PDF  7 w* setgray S88E17SP.PS / TXT / PDF S88E17SP.DAT

Table 6: For PDF linearized output with linearising data of the device (S, Q, F, O or T) in Startup (S); Input PS operator no. 2 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

*) Please transfer e. g. the PDF file S88E13SP.PS with the file S88E13SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=3. Then this PDF-file produces the same output ans the file S88E13FP.PDF of the Table 5. All L..SP files of the Table 6 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files* of Table 6 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder DE88, see
../DE.HTM in English or ../DG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.