BAM-test chart no. UE74; Colorimetric data D65
9 and 16 step separated colours for 10 hues
Colours for MRS18 and coordinates for MRS18

Colour Reproduction, Yield and/or Emission:
Colour Workflow (CW) by the input operators no. 0 cmy0* setcmykcolor and
different output PS operators and without or with MTL code for Output Linearisation (OL)


Fig. LN1: Output layout of all the L...NP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
L74E00N1.PS / TXT / JPG / PDF


Fig. LF1: Output layout of all the L...FP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
L74E00F1.PS / TXT / JPG / PDF


Fig. SF1: Output layout of all the S...FP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
S74E00F1.PS / TXT / JPG / PDF


Fig. QF1: Output layout of all the Q...FP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
Q74E00F1.PS / TXT / JPG / PDF

Remark 1: The files* of Tables 1 to 3 produce 10 pages for 10 hues and not only the first page for example shown in Fig. LN1

Remark 2: The files* of Tables 1 to 3 produce the format A4 landscape.

Remark 3: Similar files with input of "olv* setrgbcolor" instead of "cmy0* setcmykcolor" are in the directory TExx (xx=00 bis 99) instead of the directory UExx (xx=00 bis 99).

Input PS operators no. 0 cmy0* setcmykcolor
and three identical start files

*NP.PS / .TXT /.PDF
100 / 100 / 300 kByte

Output
PS operator
parameter
i*ptrsc

No colorimetric transfer from the
input PS operators no. 0 cmy0* setcmykcolor
to the output PS operators no. 0 cmy0* setcmykcolor
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device L
in files *FP.PS / TXT / PDF
200 / 200 / 300 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device L
100 kByte
L74E00NP.PS / TXT / PDF 1   L74E00FP.PS / TXT / PDF L74E00FP.DAT
S74E00NP.PS / TXT / PDF 1   S74E00FP.PS / TXT / PDF S74E00FP.DAT
Q74E00NP.PS / TXT / PDF 1   Q74E00FP.PS / TXT / PDF Q74E00FP.DAT
Table 1: Files for the PDF start and linearised output with one of three linearising data (L, S, Q) in the File (F); Input PS operators no. 0 cmy0* setcmykcolor in the NP file and equal output PS operator in the FP file.

Remark: The files* of Table 1 are intended for a PDF output with one of three linearisation data (L, S, Q) in the File (F) and not for a PS output.

Input PS operators no. 0 cmy0* setcmykcolor
and three indentical start files

*NA.PS / .TXT
100 / 100 kByte

Output
PS operator
parameter
i*ptrsc

No colorimetric transfer from the
input PS operators no. 0 cmy0* setcmykcolor
to the output PS operators no. 0 cmy0* setcmykcolor
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device L
in files *FA.PS / TXT
200 / 200 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device L
100 kByte
L74E00NA.PS / TXT 1   L74E00FA.PS / TXT L74E00FA.DAT
S74E00NA.PS / TXT 1   S74E00FA.PS / TXT S74E00FA.DAT
Q74E00NA.PS / TXT 1   Q74E00FA.PS / TXT Q74E00FA.DAT
Table 2: Files for the PS start and linearised output with one of three linearising data (L, S, Q) in the File (F); Input PS operators no. 0 cmy0* setcmykcolor in the NA file and equal output PS operator in the FP file.

Remark: The files* of Table 2 serve are intended for a PS output and not for a PDF output.

Input PS operators no. 0 cmy0* setcmykcolor
and three identical start files

*NP.PS / .TXT /.PDF
100 / 100 / 300 kByte

Output
PS operator
parameter
i*ptrsc

No colorimetric transfer from the
input PS operators no. 0 cmy0* setcmykcolor
to the output PS operators no. 0 cmy0* setcmykcolor
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device L
in files *SP.PS / TXT / PDF
200 / 200 / 300 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device L
100 kByte
L74E00NP.PS / TXT / PDF 1   L74E00SP.PS / TXT / PDF *) L74E00SP.DAT
S74G00NP.PS / TXT / PDF 1   S74G00SP.PS / TXT / PDF *) S74G00SP.DAT
Q74G00NP.PS / TXT / PDF 1   Q74G00SP.PS / TXT / PDF *) Q74G00SP.DAT
Table 3: Files for the PDF start and linearised output with one of three linearising data (L, S, Q) in the Startup (S); Input PS operators no. 0 cmy0* setcmykcolor in the NP file and equal output PS operator in the FP file.

*) Please transfer e. g. the PDF file S74E00SP.PS with the file S74E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=1. Then this PDF-file produces the same output as the file S74E00FP.PDF of the Table 1.

Remark: The files* of Table 3 are intended for a PDF output with linearisation data (L/S/Q)74E00SP.DAT in the Distiller Startup (S) directory and not for a PS output.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder UE74, see
../UE.HTM in English or ../UG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see