181101 and 040801: A/LE03/LE03Q.HTM

For this page, see LE03 in English or LG03 in German.
For the previous page, see LE02 in English or LG02 in German.
For the next page, see LE04 in English or LG04 in German.
Back to the main page of this colour series, see ../LE in English or ../LG in German.

BAM-test chart no. LE03 for printer output
16 steps: Chromatic to White and Black; Greys
1 page with 16x14 colours and 14 CIE-test colours

Measurement and CIELAB linearization: Colour Workflow (CW) by the input operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x) and
different output PS operators and without or with MTL code for Output Linearisation (OL)

Input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device Q
in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device Q
100 kByte
Q03E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor Q03E00FP.PS / TXT / PDF Q03E00FP.DAT
Q03E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray Q03E01FP.PS / TXT / PDF Q03E01FP.DAT
Q03E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q03E02FP.PS / TXT / PDF Q03E02FP.DAT
Q03E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor Q03E03FP.PS / TXT / PDF Q03E03FP.DAT
Q03E04NP.PS / TXT / PDF   4 lab* setcolor Q03E04FP.PS / TXT / PDF Q03E04FP.DAT
Q03E05NP.PS / TXT / PDF  5 LAB* setcolor Q03E05FP.PS / TXT / PDF Q03E05FP.DAT
Q03E06NP.PS / TXT / PDF  6 000n* setcmykcolor Q03E06FP.PS / TXT / PDF Q03E06FP.DAT
Q03E07NP.PS / TXT / PDF  7 w* setgray Q03E07FP.PS / TXT / PDF Q03E07FP.DAT

Table 1: Files for the PDF start and linearised output with linearising data of the device Q in the File (F); Input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x) in the NP file and output PS operators no. 0 to 7 in the FP file which are transferred by the PS MTL code.

Remark: The files* of Table 1 serve for a PDF output with linearisation data in the File (F) and not for a PS output.
* Files: L..0x, (S,Q,F,O,T)..00(NP,FP,NA,FA,SP).

Input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x)
and start files

*NA.PS / .TXT
140 / 140 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device Q
in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device Q
100 kByte
Q03E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor Q03E00FA.PS / TXT Q03E00FA.DAT
Q03E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray Q03E01FA.PS / TXT Q03E01FA.DAT
Q03E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q03E02FA.PS / TXT Q03E02FA.DAT
Q03E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor Q03E03FA.PS / TXT Q03E03FA.DAT
Q03E04NA.PS / TXT   4 lab* setcolor Q03E04FA.PS / TXT Q03E04FA.DAT
Q03E05NA.PS / TXT  5 LAB* setcolor Q03E05FA.PS / TXT Q03E05FA.DAT
Q03E06NA.PS / TXT  6 000n* setcmykcolor Q03E06FA.PS / TXT Q03E06FA.DAT
Q03E07NA.PS / TXT  7 w* setgray Q03E07FA.PS / TXT Q03E07FA.DAT

Table 2: Files for the PS start and linearised output with linearising data of the device Q in the File (F); Input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: The files* of Table 2 serve for a PS output and not for a PDF output.

Input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device Q
in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device Q
100 kByte
Q03E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor Q03E00SP.PS / TXT / PDF *) Q03E00SP.DAT
Q03E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray Q03E01SP.PS / TXT / PDF Q03E01SP.DAT
Q03E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q03E02SP.PS / TXT / PDF Q03E02SP.DAT
Q03E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor Q03E03SP.PS / TXT / PDF Q03E03SP.DAT
Q03E04NP.PS / TXT / PDF   4 lab* setcolor Q03E04SP.PS / TXT / PDF Q03E04SP.DAT
Q03E05NP.PS / TXT / PDF  5 LAB* setcolor Q03E05SP.PS / TXT / PDF Q03E05SP.DAT
Q03E06NP.PS / TXT / PDF  6 000n* setcmykcolor Q03E06SP.PS / TXT / PDF Q03E06SP.DAT
Q03E07NP.PS / TXT / PDF  7 w* setgray Q03E07SP.PS / TXT / PDF Q03E07SP.DAT

Table 3: Files for a PDF start and linearised output with linearising data of the device Q in the Startup (S); Input PS operators no. 0 (cmyn*(ORS18) setcmykcolor) (2x) in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

Remark: The files* of Table 3 serve for a PDF output with linearisation data Q03E0xSP.DAT (x=0..7) in the Distiller Startup (S) directory and not for a PS output.

*) Please transfer e. g. the PDF file Q03E00SP.PS with the file Q03E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output as the file Q03E00FP.PDF of the Table 2. All the files Q03E0xSP.PS (x=0,7) of the Table 3 are distilled with only the default file Example.ps in the Distiller Startup (S) Directory.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder LE03, see
../LE.HTM in English or ../LG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.