181212 and 030101: A/EE94/EE94.HTM

For this page, see EE94 in English or EG94 in German.
For the previous page, see EE93 in English or EG93 in German.
For the next page, see EE95 in English or EG95 in German.
Back to the main page of this colour series, see ../EE in English or ../EG in German.

For this page without and with MTL code for OL with:
CIEXYZ data of luminous colours, see JE94 in English and JG94 in German,
CJELAB data of surface colours, see EE94 in English and EG94 in German.

For this page with the image resolutions:
192 x 128 pixels, see DE94 in English or DG94 in German,
384 x 256 pixels, see EE94 in English or EG94 in German,
768 x 512 pixels, see FE94 in English or FG94 in German.

Chromatic ISO/IEC-test chart 4, LAB* input
Colour Workflow (CW) by the input operator no. 5
and different output PS operators and Output Linearisation (OL)


Fig. 1: Output layout without the MTL code in the N-File (N = No MTL code in the file), see
L94E00N1.PS / TXT / JPG / PDF


Fig. 2: Output layout with MTL code of example CIELAB output data of the device L (L=Linear) in the F-File (F = MTL code in the File), see
L94E00F1.PS / TXT / JPG / PDF

Original and important properties the image data used:
A photo of the flower motiv with the 16 step equally spaced gray scale (L*=18 to 95) and the CIE-test colours has been taken on slide film (sf) for Fig. B1 of the ISO/IEC-test chart no. 2 and on negative film (nf) for Fig. D1 of the ISO/IEC-test chart no. 4. The Kodak Photo-CD process (14 bit nonlinear) has produced the raw scan data. The grey scale data of the raw scan has been transferred to the equally spaced digital olv* image data (rgb image data). This method changes all the other image pixel data as well. The visual difference of Fig. B1 based on slide film (sf) and Fig. D1 based on negative film (nf) apears low. An output of Fig. B1 and D1 with the same resolution on monitors or printers confirms the low visual image difference.

The Output Linearisation (OL) method is not applied here to the image data of Fig. B1 or D1, e. g. in the files L..FP.PDF. The Output Linearisation (OL) method for image data will be included in one of the next versions of the MTL-Code.
For further information about the 16 step gray scales with olv* and cmyn* image data, see DE90
For further information about
Input and Output Linearization (IL and OL) for raw scan image data of slide and negative film with 32 ISO/IEC-test colours which are produced by a 5 step exposure variation, see DE36

For information about the parameter i*ptrsc (number 0 to 7) used for input or output PS operators, see DE802

For information about the ISO/IEC-test charts and separate parts (Fig. XY) with different input PS operators and discussion, see DE801

This page includes files for the following application:
Chromatic ISO/IEC-test chart 4, LAB* input,
Colour Workflow (CW) and Output Linearisation (OL)

For Output Linearisation (OL) CIELAB data are used in the files.

For Output Linearisation (OL) CIELAB data are used in the files.

Table 1 includes the output files of the Portable Document format (L..NP.PS/TXT/PDF and L..FP.PS/TXT/PDF)
Table 2 includes the output files of the PostScript format (L..NA.PS/TXT and L..FA.PS/TXT).
Table 3 includes the output files of the Portable Document format (L..NP.PS/TXT/PDF and L..SP.PS/TXT/PDF).

To indicate the Colour Workflow (CW) at the output different file names are used. The files have usually the same PS content

The PS content of the files L..NP.PS, L..NA.PS and L..SP.PS of the Tables 1 to 3 is identical and includes no MTL code.
The PS content of the files L..FP.PS and L..FA.PS of the Tables 1 and 2 is identical and includes the MTL code L..FP.DAT or L..FA.DAT in the file (F).

The output of the files L..FP.PDF and L..SP.PDF must be identical if the MTL code L..SP.DAT is stored within the Distiller Startup Directory during distilling of the PS file L..SP.PS. The files L..FP.PDF and L..SP.PDF have been produced by the software Adobe Acrobat DIstiller Version 3.0. In the first case the MTL code is located in the file L..FP.PS and in the second case the MTL code L..FP.DAT = L..SP.DAT is not in the file L..SP.PS but in the Startup (S) directory of the software Adobe Acrobat DIstiller.

Input PS operator no. 5
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 5
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
L94E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L94E00FP.PS / TXT / PDF L94E00FP.DAT
L94E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L94E01FP.PS / TXT / PDF L94E01FP.DAT
L94E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L94E02FP.PS / TXT / PDF L94E02FP.DAT
L94E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L94E03FP.PS / TXT / PDF L94E03FP.DAT
L94E04NP.PS / TXT / PDF   4 lab* setcolor L94E04FP.PS / TXT / PDF L94E04FP.DAT
L94E05NP.PS / TXT / PDF  5 LAB* setcolor L94E05FP.PS / TXT / PDF L94E05FP.DAT
L94E06NP.PS / TXT / PDF  6 000n* setcmykcolor L94E06FP.PS / TXT / PDF L94E06FP.DAT
L94E07NP.PS / TXT / PDF  7 w* setgray L94E07FP.PS / TXT / PDF L94E07FP.DAT

Table 1: For PDF output with linearising data in File (F); Input PS operator no. 5 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files* of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.

Input PS operator no. 5
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 5
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
L94E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor L94E00FA.PS / TXT L94E00FA.DAT
L94E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray L94E01FA.PS / TXT L94E01FA.DAT
L94E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor L94E02FA.PS / TXT L94E02FA.DAT
L94E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor L94E03FA.PS / TXT L94E03FA.DAT
L94E04NA.PS / TXT   4 lab* setcolor L94E04FA.PS / TXT L94E04FA.DAT
L94E05NA.PS / TXT  5 LAB* setcolor L94E05FA.PS / TXT L94E05FA.DAT
L94E06NA.PS / TXT  6 000n* setcmykcolor L94E06FA.PS / TXT L94E06FA.DAT
L94E07NA.PS / TXT  7 w* setgray L94E07FA.PS / TXT L94E07FA.DAT

Table 2: For PS output with linearising data in File (F); Input PS operator no. 5 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files* of Table 2 it is intended to produce only a PS output and not a PDF output.

The files of the tables 1 to 3 are available for different devices instead of the model device L=Linear. Every device produces with all NP files the same start output. Only for the model device L=Linear of the table 2 the output of the NP and FP in one row is identical. For devices which produce equal output for corresponding colours the output of all FP files in one collum is identical.

In application the output of the NP files for differnet output parameters i*ptrsc is in one collum often different. The output of the FP file of the devices S and Q or of the linearized output devices F, O, and T is different compared to the output of the NP file. The PS MTL code uses the measurement data of up to 256 colours of the start output, see the CIELAB LAB* data at the beginning of the FP files, for the change and the linearisation of the output.

Input PS operator no. 5
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 5
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
L94E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L94E00SP.PS / TXT / PDF L94E00SP.DAT
L94E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L94E01SP.PS / TXT / PDF L94E01SP.DAT
L94E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L94E02SP.PS / TXT / PDF L94E02SP.DAT
L94E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L94E03SP.PS / TXT / PDF *) L94E03SP.DAT
L94E04NP.PS / TXT / PDF   4 lab* setcolor L94E04SP.PS / TXT / PDF L94E04SP.DAT
L94E05NP.PS / TXT / PDF  5 LAB* setcolor L94E05SP.PS / TXT / PDF L94E05SP.DAT
L94E06NP.PS / TXT / PDF  6 000n* setcmykcolor L94E06SP.PS / TXT / PDF L94E06SP.DAT
L94E07NP.PS / TXT / PDF  7 w* setgray L94E07SP.PS / TXT / PDF L94E07SP.DAT

Table 3: For PDF output with linearising data in Startup (S); Input PS operator no. 5 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

*) Only the PDF file L94E03SP.PS is transferred with the file L94E03SP.DAT which uses the parameter i*ptrsc=3 in the Distiller Startup (S) Directory. The other L..SP files of the Table 3 are distilled with the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files* of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

The input operator no. 5 and eight output PS operators no. 0 to 7 are used in the files.The input PS operator no. 5 of the NA or NP file are transferred to the output PS operators no. 0 to 7 in the FA, FP or SP file by the PS MTL code.

For further information and discussion of the results in the achromatic case with similar files see DE811

For further information and discussion of the results in the chromatic case with similar files see DE841

Compare the final result in DE811 and DE841. The Colour Workflow (CW) and the Output Linearisation (OL) of the PS MTL code is based on ISO/IEC 15775 and DIS ISO/IEC 19839-X. The PS MTL code is compatible to CIELAB and fulfils the basic user requirements in the field of image technology. The result is the same in the achromatic and chromatic case.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder EE94, see
../EE.HTM in English or ../EG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.