181212 and 030101: A/DE19/DE19.HTM
For this page, see
DE19 in English or
DG19 in German.
For the previous page, see
DE18 in English or
DG18 in German.
For the next page, see
DE20 in English or
DG20 in German.
Back to the main page of this colour series, see
../DE in English or
../DG in German.
Remark 1: The output result
produced is the same for the four methods, see the URL DE09
Remark 2: The output result produced here by File Output Linearisation
(OLF) is based on measurement of the LAB* CIELAB
data instead of only lightness L* data used in DE09
For similar Methods to produce a start and linearized output for a single Figure or many Figures of the ISO/IEC-test charts or the complete ISO/IEC-test charts, see DE00
For the accuracy of the Start and Linearized printer output for the digital 16 step colour series, see DE14L
1. Output Linearization (OL) of the ISO/IEC-test chart no. 3
Step S1: Start output of the 16 grey steps.
Remark: The measurement data of CIELAB LAB* of the 16 grey
steps are used to produce an linearized output.
Step S2: linearized output of the 16 equidistant grey steps
in CIE lightness L*
Step S3 (optional): Specification of the reproduction
properties of the start output and the linearized
output according to the method given in Annex G of ISO/IEC
15775: 1999-12.
Short description of the method using
the PS output method for device T:
1. The file A/DE19/10T/T10E00NA.PS
is used to produce a PS ouput on a PS printer.
2. The 16 LAB*-CIELAB data of the 16 gray steps
of the output NA are measured in the sequence F to 0.
3. The 16 LAB*-CIELAB data of the output NA
are included in the files FA and RA (R=result, optional
not listed here, for the accuracy data as table and figure see DE14L).
4. The file A/DE19/10T/T10E00FA.PS
is used to produce the linearized PS ouput on a PS printer.
5. The 16 LAB*-CIELAB data of the 16 gray steps
of the output FA are measured in the sequence F to 0.
6. The 16 L*-lightness data of the output FA
are included in the file RA (R=result, optional,
not listed here, see the accuracy data as table and figure see DE14L).
Remark: For a PDF output on any printer (instead of the PS output
on a PS printer) the software Adobe Acrobat Distiller or
an equivalent is necessary. The software is used to produce PDF
files from PS files.
Output linearization of the achromatic ISO/IEC-test chart no. 3
If the start printer output of the ISO/IEC-test chart fails to pass some of the ISO/IEC-tests according to ISO/IEC 15775, e. g. to recognize 16 grey steps or at least 5 of the 8 Landolt -rings in a row, then there is the intention for an linearized printer output.
At least the actual measurement data of lightness L* (or the LAB* CIELAB data) for the colours 48 to 63 (colour series N W ) must be included in the digital file FP.PS, e. g. T10E00FP.PS, arround the line number 83 to produce a linearized output.
Remark 1: In the file T10E00FP.PS the PS operator 0 0 0 n* setcmykcolor is used and therefore the CIELAB data of the colour series N W must be changed.
Remark 2: The CIELAB data of the colours 112 to 128 (colour series A W) must be changed if the PS operator c* m* y* 0 setcmycolor is used in the digital file T10E00FP.PS. The change must be arround the line number 147 to produce a linearized output. This is not the case in the following files FP.PS.
2. No Output Linearization (OLN)
to produce the start output (Step S1)
ISO/IEC-test
chart no. 3 (N=No Output Linearization) |
Format PS and Portable Document Format (Version 3.0), File extention NA.PS, NA.TXT, and NA.PDF | Format PS and Portable Document Format (Version 3.0), File extention NP.PS, NP.TXT, and NP.PDF |
Printer x=A, PS and PDF output method |
119 / 119 /39 kByte |
119 / 119 / 39 kByt e |
Printer x=F, PS output method only |
119 / 119 /39 kByte |
|
Printer x=O, PS and PDF output method |
119 / 119 /39 kByte |
119 / 119 / 39 kByt e |
Printer x=T, PS and PDF output method |
119 / 119 /39 kByte |
119 / 119 / 39 kByt e |
3. File Output Linearization (OLF) to produce the linearized output (step S2)
At least the actual measurement lightness
L* data (or the LAB* CIELAB data)
for the colours 48 to 63 (colour series N W) of the
file NP.PS, e. g. T10E00NP.PS, must be included in the
digital file FP.PS, e. g. T10E00FP.PS, arround the line
number 83 to produce a linearized output of an actual printer.
ISO/IEC-test
chart no. 3 (F=File Output Linearization) |
Format PS and Portable Document Format (Version 3.0), File extention FA.PS, FA.TXT, and FA.PDF | Format PS and Portable Document Format (Version 3.0), File extention FP.PS, FP.TXT, and FP.PDF |
Printer x=A, PS and PDF output method |
119 / 119 /39 kByte |
119 / 119 / 39 kByt e |
Printer x=F, PS output method only |
119 / 119 /39 kByte |
|
Printer x=O, PS and PDF output method |
119 / 119 /39 kByte |
119 / 119 / 39 kByt e |
Printer x=T, PS and PDF output method |
119 / 119 /39 kByte |
119 / 119 / 39 kByt e |
Remark: Other grey output possibilities
are in preparation (compare DE09), such as
1. w* setgray
2. n* n* n* 0 setcmykcolor
3. w* w* w* setrgbcolor
In general each output is different using one of the methods no.
1 to 3 compared to the method used here (0 0 0 n* setcmykcolor).
-------
For an introduction (archive 2000-2009) to all folders
compared to this folder DE19, see
../DE.HTM in English or
../DG.HTM in German.
For information (archive 2000-2009) about International and
National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.
For information (archive 2000-2009) about colour test charts
and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.
For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.
Back to the main page of the TU web site
(not archive), see
../../index.html in English or
../../indexDE.html in German.
The last link may not work, if you have visited
directly this archive site.
Then go to the main page of one of the
two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.