181212 and 030101: A/DE11/DE11.HTM

For this page, see DE11 in English or DG11 in German.
For the previous page, see DE10 in English or DG10 in German.
For the next page, see DE12 in English or DG12 in German.
Back to the main page of this colour series, see ../DE in English or ../DG in German.

Start and linearized printer output of the ISO/IEC-test chart no. 4 (Series W - OLVN, printer range)
according to ISO/IEC 15775:1999-12
There are at least three different methods to linearize the printer output:
1. By Linearization Method data (CIELAB data and PS code) in the PS file (F)
2. By colour manangement data in the Distiller Startup (S) directory
3. By Linearization Method data in the PostScript device (D) memory
Remark 1: The output result produced is the same for the three methods, see the URL DE09
Remark 2: The file names and tables in this directory include only files for No and File Linearization Method (N and F).

For similar Methods to produce a start and linearized output for a single Figure or many Figures of the ISO/IEC-test charts or the complete ISO/IEC-test charts, see DE00

There are three steps S1, S2, and S3 recommended here:
Step S1: Start output
of the four 16step colour series W ­OLVN between the colour white W (paper white) and the four colours OLVN(C=M=Y).
Remark: The output measurement data are used to produce the linearized output. For linearization the CIELAB data of the four 16step colour series W ­ CMYN (4 x 16 x 3 data) of step S1 are necessary and must be included in the file of step S2.
Step S2: linearized output of the four 16step colour series which are approximately equidistant in CIELAB colour space.
Step S3: Specification of the reproduction properties of the start output and the linearized output according to the method given in Annex G of DIN 33866-1:2000-08 and ISO/IEC 15775:1999-12.

Short description of the method using the PS output method for the device T:
1. The file A/DE11/10T/T10E00NA.PS is used to produce the start PS ouput on a PS printer.
2. The four 16step colour series of the output NA are measured in the sequence F to 0 (from the colour to the white).
3. The four 16step CIELAB colour data of the output NA are included in the file FA.
4. The file A/DE11/
10T/T10E00FA.PS is used to produce the linearized PS ouput on a PS printer.
5. The four 16step colour series of the output FA are measured in the sequence F to 0 (from the colour to the white).
6. The four 16step CIELAB colour data of the output NA (step S1) and FA (step S2) are included in the file RA (R=result).

Remark: For a start and linearized PDF output on any printer (instead of the PS output on a PS printer) the software Adobe Acrobat Distiller or an equivalent is necessary. The software is used to produce PDF files from the PS files.

1. Output linearization of the achromatic ISO/IEC-test chart no. 2

If the start printer output of the ISO/IEC-test chart fails to pass some of the ISO/IEC-tests according to ISO/IEC 15775, e. g. to recognize the 16 steps of the 16step colour series or all the Landolt -rings, then there is the intention for an linearized printer output. The following URL shows examples for the specification of the reproduction properties of the start output and the linearized output according to the method given in Annex G of DIN 33866-1:2000-08 and ISO/IEC 15775:1999-12.

Remark 1: The accuracy of the ISO/IEC-Test chart output is described in DE10

Remark 2: An important exercise in four steps which is recommended for visual linearization of the output and which may be used for any printer, monitor or a video-beamer is given four a black and white printer by the URL DE09.

2. No (=N) Linearization Method for the start output (step S1) of the chromatic ISO/IEC-test chart no. 2 on four real printers (X=A,F,O,T) by the file formats PS, PDF, GIF and HTM_GIF (html)

File of ISO/IEC-test chart no. 4
(N=No Linearization Method)
Format PS,
File extention NA.PS and NA.TXT
Format PS and Portable Document Format (Version 3.0), File extention NP.PS and NP.PDF Format GIF (GIF89)
(olv*, 72 ppi), File extention NG.PS and NG.GIF
Format HTM_GIF89
(olv*, 72 ppi), File extention NH.PS and NH.HTM
 
T10E00
series: w ­ olvn

T10E00NA .PS / .TXT
119 kByte

T10E00NP .PS / TXT / PDF
119 / 39 kByt.

T10E00NG.PS /.TXT /.GIF
120 / 120 / 36 kB

T10E00NH.PS /.TXT /.HTM
120 / 120 / 40 kB

3. File (=F) Linearization Method to produce the linearized output (step S2) of the chromatic ISO/IEC-test chart no. 2 on one real printer X=T; file formats PS, PDF, GIF and HTM (html)

File of ISO/IEC-test chart no. 4
(F=File Linearization Method)
Format PS,
File extention FA.PS and FA.TXT
Format PS and Portable Document Format (Version 3.0), File extention FP.PS and FP.PDF Format GIF (GIF89)
(olv*, 72 ppi), File extention FG.PS and FG.GIF
Format HTM_GIF89
(olv*, 72 ppi), File extention FH.PS and FH.HTM
 
T10E00
series: w ­ olvn

T10E00FA .PS / .TXT
119 kByte

T10E00FP .PS / TXT / PDF
119 / 39 kByt.

T10E00FG.PS /.TXT /.GIF
120 / 120 / 36 kB

T10E00FH.PS /.TXT /.HTM
120 / 120 / 40 kB

The PostScript operator cmyn* setcmykcolor is used for both the start and the linearized output

-------
For an introduction (archive 2000-2009) to all folders compared to this folder DE11, see
../DE.HTM in English or ../DG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.