190101 and 081201: A/Ge.HTM

For this page in German, see Gg

For the preceding page, see Fe in English or Fg in German.
For the next page, see IE in English or IG in German.

D65 and D50 colour tables (olv, cmy, LAB*, LCH*, ncu*, etc.) for 1080 device standard colours
Real device output (Offset ORS20_95, L*=20_95)
Standard device output (Offset ORS18_95, L*=18_95)
without and with LAB* linearisation in the folder Gexx
(e=English, xx=00 to 99)

D65 colour tables (olv, cmy, LAB*, LCH*, ncu*, etc.) for 1080 device standard colours
Real device output (Offset ORS20_95, L*=20_95) without and with LAB* linearisation.
Interpretation of colour data (rgb, cmy0, n, w) with 5 transfer methods
olv*, cmy0*, cmyn6*, cmyn4*, cmyn5* for the CIE standard illuminant D65

Interpretation of colour data (rgb, cmy0, n, w) with olv* transfer, Ge00
Example file (12 pages, 1,9 MByte) Ge00/10L/L00e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmy0* transfer, Ge01
Example file (12 pages, 1,9 MByte) Ge01/10L/L01e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn6* transfer, Ge02
Example file (12 pages, 1,9 MByte) Ge02/10L/L02e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn4* transfer, Ge03
Example file (12 pages, 1,9 MByte) Ge03/10L/L03e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with ocmyn5* transfer, Ge04
Example file (12 pages, 1,9 MByte) Ge04/10L/L04e00NP.PDF

D65 colour tables (olv, cmy, LAB*, LCH*, ncu*, etc.) for 1080 device standard colours
Real device output (Offset ORS20_95, L*=20_95) without and with LAB* linearisation
Interpretation of colour data (rgb, cmy0, n, w) with 5 fransfer methods
olv*, cmy0*, cmyn6*, cmyn4*, cmyn5* for the CIE standard illuminant D65 and
with lookup tables (LUT) rgb, cmy0, LAB* of CIE and ICC data.

Interpretation of colour data (rgb, cmy0, n, w) with olv* transfer, Ge05
Example file (25 pages, 2 MByte) Ge05/10L/L05e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmy0* transfer, Ge06
Example file (25 pages, 2 MByte) Ge06/10L/L06e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn6* transfer, Ge07
Example file (25 pages, 2 MByte) Ge07/10L/L07e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn4* transfer, Ge08
Example file (25 pages, 2 MByte) Ge08/10L/L08e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmyn5* transfer,
Ge09
Example file (25 pages, 2 MByte) Ge09/10L/L09e00NP.PDF




D65 colour tables (olv, cmy, LAB*, LCH*, ncu*, etc.) for 1080 device standard colours
Real device output (Offset ORS20_95, L*=20_95) without and with LAB* linearisation.
Interpretation of colour data (rgb, cmy0, n, w) with 5 transfer methods
olv*, cmy0*, cmyn6*, cmyn4*, cmyn5* for the CIE illuminant D50

Interpretation of colour data (rgb, cmy0, n, w) with olv* transfer, Ge10
Example file (12 pages, 1,9 MByte) Ge10/10L/L10e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmy0* transfer,
Ge11

Example file (12 pages, 1,9 MByte) Ge11/10L/L11e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn6* transfer, Ge12
Example file (12 pages, 1,9 MByte) Ge12/10L/L12e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn4* transfer, Ge13
Example file (12 pages, 1,9 MByte) Ge13/10L/L13e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn5* transfer, Ge14
Example file (12 pages, 1,9 MByte) Ge14/10L/L14e00NP.PDF

D65 colour tables (olv, cmy, LAB*, LCH*, ncu*, etc.) for 1080 device standard colours
Real device output (Offset ORS20_95, L*=20_95) without and with LAB* linearisation.
Interpretation of colour data (rgb, cmy0, n, w) with 5 fransfer methods
olv*, cmy0*, cmyn6*, cmyn4*, cmyn5* for the CIE illuminant D50 and
with lookup tables (LUT) rgb, cmy0, LAB* of CIE and ICC data.

Interpretation of colour data (rgb, cmy0, n, w) with olv* transfer,
Ge15
Example file (25 pages, 2 MByte) Ge15/10L/L15e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmy0*transfer, Ge16
Example file (25 pages, 2 MByte) Ge16/10L/L16e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn6* transfer, Ge17
Example file (25 pages, 2 MByte) Ge17/10L/L17e00NP.PDF

Interpretation of colour data (rgb, cmy0, n, w) with cmyn4* transfer, Ge18
Example file (25 pages, 2 MByte) Ge18/10L/L18e00NP.PDF



Interpretation of colour data (rgb, cmy0, n, w) with cmyn5* transfer, Ge19
Example file (25 pages, 2 MByte) Ge19/10L/L19e00NP.PDF


D65 colour tables (olv, cmy, LAB*, LCH*, ncu*, etc.) for 1080 device standard colours
Standard device output (Offset ORS18_95, L*=18_95) without and with LAB* linearisation
Interpretation of colour data (rgb, cmy0, n, w) with 5 fransfer methods
olv*, cmy0*, cmyn6*, cmyn4*, cmyn5* for the CIE standard illuminant D65 and
with lookup tables (LUT) rgb, cmy0, LAB* of CIE and ICC data.

Interpretation of colour data (rgb, cmy0, n, w) with olv* transfer, Ge20
Example file (25 pages, 2 MByte) Ge20/10L/L20e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmy0* transfer, Ge21
Example file (25 pages, 2 MByte) Ge21/10L/L21e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmyn6* transfer, Ge22
Example file (25 pages, 2 MByte) Ge22/10L/L22e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmyn5* transfer, Ge23
Example file (25 pages, 2 MByte) Ge23/10L/L23e00NP.PDF


Interpretation of colour data (rgb, cmy0, n, w) with cmyn4* transfer, Ge24
Example file (25 pages, 2 MByte) Ge24/10L/L24e00NP.PDF

-------
For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
4STAE.html in English or
4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
indexAE.html in English or
indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
XY91AE.html in English or
XY91AG.html in German.

back to the main page of the TU web site
../index.html in English.

The last link may not work, if you have visited directly this archive site. Then go to the main page of one of the two TU web sites in a new window
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.